DAILY POWER SYSTEM HIGHLIGHTS FOR MARCH 3, 2004

Date
3 March 2004
Category
Essential Services
Text available
English
Files
1
English original DOCDownload English text
DAILY POWER SYSTEM HIGHLIGHTS FOR MARCH 3, 2004 The CPA Electricity Advisor issues this report to note significant events or conditions of interest in the power sector. The basic daily data on the power system is available on the CPA web site. HIGHLIGHTS: Generation: Peak Power 3945Mw, 86,575Mw hours, 7-day Avg. 4078Mw Generators Returned to Service: None reported Generators Unscheduled Out of Service 783 Mw PLANT Type SP, CP, RP, HP Fault Mw Dibis 2 SP Boiler Leak 8 Baiji 6 SP Trip Valve 100 South Baghdad 4 SP Boiler Leak 30 Mussaibe 1 SP Boiler Leak 200 Hartha 4 SP Boiler Leak 80 Baiji 2, CP Lubricating oil leak 110 Hilla 2 CP Servo 20 Khor Zubayr 3 CP Generator Transf. Prob. 50 Mosil 1 CP Rotor Defect 15 Mosil 9 CP Rotor Defect 15 Old Mulla 1 CP Acc Gear 15 Old Mulla 2 CP Servo 15 Najaf 2 CP Bearing oil leak 50 New Mulla 6 CP Generator Defect 30 Taji 3, CP Compressor 15 Taji 4 CP Control card 15 Taji Mobile, 2 CP Software problem 15 * RED – Denotes out of service since last report Generators Scheduled Out of Service 1166 Mw PLANT Type SP/NG Prog. Maintenance(M) / Rehab (R) Maint. Org. Date out-of -service Est. In-service Date Mw Baiji 2 SP M Bechtel 2 Jan 04 4 Mar 100 Baiji 3 SP M GRD/RIE 29 Feb 04 30 Jun 100 Doura 2 CP M ME 21 Feb 04 TBD 20 Doura 3 CP R GRD/RIE 1 Mar 03 15 May 20 Doura 4 SP M ME 2 Feb 04 20 Apr 65 Doura 5 SP R Bechtel Jul 03 30 Apr 100 Doura 6 SP R Bechtel Jul 03 31May 100 Dibis 3 SP M ME 30Dec 03 31 May 8 Dibis 4 CP R GRD/RIE Sep 03 30 Mar 18 Khor Zubayr 2 CP M ME 19 Feb 04 30 Apr 50 Mosul 8 CP M ME 28 Feb 04 TBD 15 Mussaibe 2 SP M ME 28 Feb 04 28 Apr 200 Mussaibe 4 SP M ME 7 Feb 04 7 Mar 200 New Mulla 2 CP M ME 17 Feb04 TBD 30 Old Mulla 5 CP M GRD/RIE 1 Nov 03 15 May 15 Old Mulla 8 CP M GRD/RIE 28 Feb 04 15 May 15 Old Mulla 12 CP R GRD/RIE 1 Oct 03 15 May 15 Taji 7 CP R GRD/RIE 1 Oct 03 15 May 15 Shuaiba 1 CP M ME 14 Feb 04 31 May 20 South Baghdad 1 SP M ME 12 Feb 04 12 Apr 30 South Baghdad 2 SP M ME 12 Feb 04 12 Apr 30 LEGEND OF ELECTRICAL SYSTEM POWER SOURCE SP: STEAM POWER – These plants use either fuel oil or crude in burners CP: COMBUSTION POWER RP: RECIPROCATING POWER HP: HYDRO POWER Transmission: LINE Kv Fault Maint. Org. Date out-of -service Est. In-service Date Comments Nassiriya-Khor Zubayr 400 Sabotage Bechtel 26 May 102 towers complete/212req’d Haditha-Baghd West 400 Sabotage GRD/RIE 15 Apr 101 towers complete/236 req’d Hartha-Qut – Wasit 400 Sabotage GRD/RIE 7 Mar 293 towers complete/297 req’d Baiji - Baghd West #1 400 Sabotage GRD/RIE 22 Mar 68 towers complete/68 req’d Baghd E.-Baghd S. #2 400 New Line GRD/RIE 3 Mar 81 towers complete/81req’d Baghd S. – Diwaniyah 400 Sabotage GRD/RIE Compl. 24 Jan 27 towers complete/27 req’d Haditha – Qaim 400 Sabotage ME TBD No contract awarded Baiji – Haditha 400 Sabotage ME TBD No contract awarded Diyala Connection 400 New Line ME 30 Apr Dibis/Irbil-Quarqush 132 New Line GRD/RIE 15 May Contractor on-site 20 Feb Mosul – Mosul East 132 Sabotage ME TBD Shuwaiba-Toba-Hamar 132 Sabotage ME 28 Feb 44 towers complete/44 req’d Baghd West – Jamia 132 Sabotage ME TBD Omara-Burzegan 132 Looting ME 1 May 26 towers complete/126 req’d Temim- Tuz 132 Sabotage ME TBD Nejibiya – Hartha 132 Sabotage ME TBD Lines Returned to service: None reported today Distribution: Report Date - 03 MARCH 2004 Power transferred from North to Middle 820 MW. Power transferred from South to Middle 265 MW. GOVERNORATE Peak Load MW MWH Average Load MW Baghdad 1315 Duhok 85 Naynawa 365 Tamim 120 Salah Aldeen 192 Anbar 210 Dyala 94 Babil 90 Kirbala 130 Najaf 148 Kadsya 60 Wasit 85 Muthana 65 Nasirya 125 Misan 65 Basra 310 Data compiled and reported by: LTC Tharnell M. Thomas CENTCOM LNO CPA Ministry of Electricity thomast2orha.centcom.mil Page PAGE 1 of NUMPAGES 3