DABV01-04-R-0008 Rustimiyah Final Load List

Date
Unknown
Category
Business
Text available
English
Files
1
English original XLSDownload English text

Spreadsheet preview

Sheet “load list 1”: 12 rows × 24 columns

NameplateCoect.Ope-StarterBreakerCableSchematicVendorFieldSpareDATA SOURCE
MCCcubicleEngravingConnectedratingLRCSefty factorOverDrawingDataTOComponents
RevCubiclevolume(Description)LoadFLAFLASizeTypeMCPGndLoadFrameTripSizeNo.SheetChangeAvailableREMARKS
A1Incoming main circuit breaker400ESTIMATE
A2High Voltage Room30ESTIMATE
A3Lighting/Receptacles (Sockets)60ESTIMATE
A4Guard Rooms60ESTIMATE
A5Spare100ESTIMATE
A6Spare60ESTIMATE
A7Spare30ESTIMATE
1) Provide the following MCB in the lighting cubicle: 1- 3P, 40A; 2 - 2P, 25A; 2 - 2P, 16A; 2 - 2P10A; 2 -2P, 6A
2) IP 42
# load list 1 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare DATA SOURCE MCC cubicle Engraving Connected rating LRC Sefty factor Over Drawing Data TO Components Rev Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS A 1 Incoming main circuit breaker 400 ESTIMATE A 2 High Voltage Room 30 ESTIMATE A 3 Lighting/Receptacles (Sockets) 60 ESTIMATE A 4 Guard Rooms 60 ESTIMATE A 5 Spare 100 ESTIMATE A 6 Spare 60 ESTIMATE A 7 Spare 30 ESTIMATE 1) Provide the following MCB in the lighting cubicle: 1- 3P, 40A; 2 - 2P, 25A; 2 - 2P, 16A; 2 - 2P10A; 2 -2P, 6A 2) IP 42 # load list 2 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC IP Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming main circuit breaker 200 Fed From main panel in power house. See sketch #4 2 Air Circulation Fan 5 KW 10 9 1 FVNR 20 2 mode operating auto- hand 3 Water pump #1 3.5 KW 7 6 1 FVNR 15 2 mode operating auto- hand 4 Water pump #2 3.5 KW 7 6 1 FVNR 15 2 mode operating auto- hand 5 Compressor #1 37 KW 75 60 3 Star Delta 125 2 mode operating auto- hand 6 Compressor #2 37 KW 75 60 3 Star Delta 125 2 mode operating auto- hand 7 Spare 30 8 (Empty Cubicle) # load list3C Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC Safety factor Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 90 KW Pump Motor 90 KW 6 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 2 160 KW Pump Motor 160 KW 6 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 3 160 KW Pump Motor 160 KW 6 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 4 250 KW Pump Motor 250 KW 7 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 5 Spare 250 KW 7 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. Specification of Main Lift Pumping Station U2 : 1. Provide draw-able starters (C.B + contactors + control). 2. Provide auto-transformer starting which give motor 35% then 75% then full voltage with all protection for motor and cables. 3. Provide remote start-stop. 4. Provide auto/off/hand selector switch, auto by water level control system. 5. Provide all required cable termination boxes # load list 3D Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC Safety factor Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 90 KW Pump Motor 90 KW 6 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 2 160 KW Pump Motor 160 KW 6 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 3 160 KW Pump Motor 160 KW 6 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 4 250 KW Pump Motor 250 KW 7 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. 5 Spare 250 KW 7 Auto-transformer Sketch #3 Ampmeter, voltmeter, selector switches, start/stop/fault lights and protective relaying to be included. Specification of Main Lift Pumping Station U2 : 1. Provide draw-able starters (C.B + contactors + control). 2. Provide auto-transformer starting which give motor 35% then 75% then full voltage with all protection for motor and cables. 3. Provide remote start-stop. 4. Provide auto/off/hand selector switch, auto by water level control system. 5. Provide all required cable termination boxes # load list 3A Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC Safety factor Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker A 630 400 4*150mm^2 Sketch #3 Ampmeter, voltmeter, selector switches, and protective relaying to be included. 2 Incoming Main Circuit Breaker B 630 400 4*150mm^2 Sketch #3 Ampmeter, voltmeter, selector switches, and protective relaying to be included. Specification of Main Lift Pumping Station U2 : 1. Provide draw-able starters (C.B + contactors + control). 2. Provide all required cable termination boxes. # load list 3B Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC Safety factor Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming MCC Circuit Breaker A 630 400 4*150mm^2 Sketch #3 Ampmeter, voltmeter, selector switches, and protective relaying to be included. 2 Incoming MCC Circuit Breaker B 630 400 4*150mm^2 Sketch #3 Ampmeter, voltmeter, selector switches, and protective relaying to be included. 3 Bus Tie Breaker 630 400 4*150mm^2 Sketch #3 Bus tie breaker to be interlocked to avoid paralleling of incoming supply. Ampmeter, voltmeter, selector switches, and protective relaying to be included. Specification of Main Lift Pumping Station U2 : 1. Provide draw-able starters (C.B + contactors + control). 2. Provide all required cable termination boxes. # load list 4 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker 2000 Sketch #4 Fed from TR.11.2 1MVA, transformer earth fault protection relay (50N) shall be provided in addition of breaker protection. 2 Raw Sludge Pump Station U5 MCC 400 Sketch #4 Provide ampmeter and selector switch. 3 Raw Sludge Pump Station U5 MCC 400 Sketch #4 Provide ampmeter and selector switch. 4 Main Lift Pump Station U2 MCC Feeder A 200 Sketch #4 Provide ampmeter and selector switch. 5 Main Lift Pump Station U2 MCC Feeder B 200 Sketch #4 Provide ampmeter and selector switch. 6 Administration Building Pwr Dist Pnl 200 Sketch #4 7 Air Chiller MCC 200 Sketch #4 Provide ampmeter and selector switch. 8 Raw Sludge Pump Station U5 & U6 MCC 200 Sketch #4 Provide ampmeter and selector switch. 9 Air Chiller Blower MCC 100 Sketch #4 Provide ampmeter and selector switch. 10 Detritors U4 MCC 100 Sketch #4 Provide ampmeter and selector switch. 11 Lighting/Receptacles 60 Sketch #4 12 Potable Water MCC 30 Sketch #4 Provide ampmeter and selector switch. 13 Generator #1 30 Sketch #4 14 Generator #2 30 Sketch #4 15 Generator #3 30 Sketch #4 16 Grease Removal MCC 30 Sketch #4 Provide ampmeter and selector switch. 17 Spare 200 Sketch #4 18 Spare 100 Sketch #4 19 Spare 100 Sketch #4 20 Spare 30 Sketch #4 # load list 5 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC sefty Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA factor Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Circuit Breaker -Transformer TR12.1 2500 Sketch #5 Transformer ground fault protection relay (50N) shall be provided in addition of breaker protection. Provide Voltmeter, Ampmeter and selector switches. 2 Incoming Circuit Breaker -Transformer TR12.2 2500 Sketch #5 Transformer ground fault protection relay (50N) shall be provided in addition of breaker protection. Provide Voltmeter, Ampmeter and selector switches. 3 Bus Tie Circuit Breaker 2000 Sketch #5 3NO. Bus Tie circuit breaker to be interlocked to avoid apralleling of incoming supply. Ampmeter, voltmeter, selector switches and protective relaying to be included 4 Aeration Motor A1 37 KW 4 FVNR Sketch #5 3NO. 5 Aeration Motor A2 37 KW 4 FVNR Sketch #5 3NO. 6 Aeration Motor A3 37 KW 4 FVNR Sketch #5 7 Aeration Motor A4 37 KW 4 FVNR Sketch #5 8 Aeration Motor A5 37 KW 4 FVNR Sketch #5 9 Aeration Motor B1 37 KW 4 FVNR Sketch #5 10 Aeration Motor B2 37 KW 4 FVNR Sketch #5 11 Aeration Motor B3 37 KW 4 FVNR Sketch #5 12 Aeration Motor B4 37 KW 4 FVNR Sketch #5 13 Aeration Motor B5 37 KW 4 FVNR Sketch #5 14 Aeration Motor C1 37 KW 4 FVNR Sketch #5 15 Aeration Motor C2 37 KW 4 FVNR Sketch #5 16 Aeration Motor C3 37 KW 4 FVNR Sketch #5 17 Aeration Motor C4 37 KW 4 FVNR Sketch #5 18 Aeration Motor C5 37 KW 4 FVNR Sketch #5 19 Aeration Motor D1 37 KW 4 FVNR Sketch #5 20 Aeration Motor D2 37 KW 4 FVNR Sketch #5 21 Aeration Motor D3 37 KW 4 FVNR Sketch #5 22 Aeration Motor D4 37 KW 4 FVNR Sketch #5 23 Aeration Motor D5 37 KW 4 FVNR Sketch #5 24 Spare 37 KW 4 FVNR Sketch #5 25 Spare 37 KW 4 FVNR Sketch #5 26 Aeration Motor E1 7.5 KW 2 FVNR Sketch #5 27 Aeration Motor E2 7.5 KW 2 FVNR Sketch #5 28 Aeration Motor E3 7.5 KW 2 FVNR Sketch #5 29 Aeration Motor E4 7.5 KW 2 FVNR Sketch #5 30 Aeration Motor E5 7.5 KW 2 FVNR Sketch #5 31 Aeration Motor E6 7.5 KW 2 FVNR Sketch #5 32 Aeration Motor E7 7.5 KW 2 FVNR Sketch #5 33 Aeration Motor E8 7.5 KW 2 FVNR Sketch #5 34 Aeration Motor E9 7.5 KW 2 FVNR Sketch #5 35 Aeration Motor E10 7.5 KW 2 FVNR Sketch #5 36 Aeration Motor F1 7.5 KW 2 FVNR Sketch #5 37 Aeration Motor F2 7.5 KW 2 FVNR Sketch #5 38 Aeration Motor F3 7.5 KW 2 FVNR Sketch #5 39 Aeration Motor F4 7.5 KW 2 FVNR Sketch #5 40 Aeration Motor F5 7.5 KW 2 FVNR Sketch #5 41 Aeration Motor F6 7.5 KW 2 FVNR Sketch #5 42 Aeration Motor F7 7.5 KW 2 FVNR Sketch #5 43 Aeration Motor F8 7.5 KW 2 FVNR Sketch #5 44 Aeration Motor F9 7.5 KW 2 FVNR Sketch #5 45 Aeration Motor F10 7.5 KW 2 FVNR Sketch #5 46 Aeration Motor G1 7.5 KW 2 FVNR Sketch #5 47 Aeration Motor G2 7.5 KW 2 FVNR Sketch #5 48 Aeration Motor G3 7.5 KW 2 FVNR Sketch #5 49 Aeration Motor G4 7.5 KW 2 FVNR Sketch #5 50 Aeration Motor G5 7.5 KW 2 FVNR Sketch #5 51 Aeration Motor G6 7.5 KW 2 FVNR Sketch #5 52 Aeration Motor G7 7.5 KW 2 FVNR Sketch #5 53 Aeration Motor G8 7.5 KW 2 FVNR Sketch #5 54 Aeration Motor G9 7.5 KW 2 FVNR Sketch #5 55 Aeration Motor G10 7.5 KW 2 FVNR Sketch #5 56 Aeration Motor H1 7.5 KW 2 FVNR Sketch #5 57 Aeration Motor H2 7.5 KW 2 FVNR Sketch #5 58 Aeration Motor H3 7.5 KW 2 FVNR Sketch #5 59 Aeration Motor H4 7.5 KW 2 FVNR Sketch #5 60 Aeration Motor H5 7.5 KW 2 FVNR Sketch #5 61 Aeration Motor H6 7.5 KW 2 FVNR Sketch #5 62 Aeration Motor H7 7.5 KW 2 FVNR Sketch #5 63 Aeration Motor H8 7.5 KW 2 FVNR Sketch #5 64 Aeration Motor H9 7.5 KW 2 FVNR Sketch #5 65 Aeration Motor H10 7.5 KW 2 FVNR Sketch #5 66 Aeration Motor I1 7.5 KW 2 FVNR Sketch #5 67 Aeration Motor I2 7.5 KW 2 FVNR Sketch #5 68 Aeration Motor I3 7.5 KW 2 FVNR Sketch #5 69 Aeration Motor I4 7.5 KW 2 FVNR Sketch #5 70 Aeration Motor I5 7.5 KW 2 FVNR Sketch #5 71 Aeration Motor I6 7.5 KW 2 FVNR Sketch #5 72 Aeration Motor I7 7.5 KW 2 FVNR Sketch #5 73 Aeration Motor I8 7.5 KW 2 FVNR Sketch #5 74 Aeration Motor I9 7.5 KW 2 FVNR Sketch #5 75 Aeration Motor I10 7.5 KW 2 FVNR Sketch #5 76 Aeration Motor J1 7.5 KW 2 FVNR Sketch #5 77 Aeration Motor J2 7.5 KW 2 FVNR Sketch #5 78 Aeration Motor J3 7.5 KW 2 FVNR Sketch #5 79 Aeration Motor J4 7.5 KW 2 FVNR Sketch #5 80 Aeration Motor J5 7.5 KW 2 FVNR Sketch #5 81 Aeration Motor J6 7.5 KW 2 FVNR Sketch #5 82 Aeration Motor J7 7.5 KW 2 FVNR Sketch #5 83 Aeration Motor J8 7.5 KW 2 FVNR Sketch #5 84 Aeration Motor J9 7.5 KW 2 FVNR Sketch #5 85 Aeration Motor J10 7.5 KW 2 FVNR Sketch #5 86 Aeration Motor K1 7.5 KW 2 FVNR Sketch #5 87 Aeration Motor K2 7.5 KW 2 FVNR Sketch #5 88 Aeration Motor K3 7.5 KW 2 FVNR Sketch #5 89 Aeration Motor K4 7.5 KW 2 FVNR Sketch #5 90 Aeration Motor K5 7.5 KW 2 FVNR Sketch #5 91 Aeration Motor K6 7.5 KW 2 FVNR Sketch #5 92 Aeration Motor K7 7.5 KW 2 FVNR Sketch #5 93 Aeration Motor K8 7.5 KW 2 FVNR Sketch #5 94 Aeration Motor K9 7.5 KW 2 FVNR Sketch #5 95 Aeration Motor K10 7.5 KW 2 FVNR Sketch #5 96 Aeration Motor L1 7.5 KW 2 FVNR Sketch #5 97 Aeration Motor L2 7.5 KW 2 FVNR Sketch #5 98 Aeration Motor L3 7.5 KW 2 FVNR Sketch #5 99 Aeration Motor L4 7.5 KW 2 FVNR Sketch #5 100 Aeration Motor L5 7.5 KW 2 FVNR Sketch #5 101 Aeration Motor L6 2 FVNR Sketch #5 102 Aeration Motor L7 7.5 KW 2 FVNR Sketch #5 103 Aeration Motor L8 7.5 KW 2 FVNR Sketch #5 104 Aeration Motor L9 7.5 KW 2 FVNR Sketch #5 105 Aeration Motor L10 7.5 KW 2 FVNR Sketch #5 106 Spare 7.5 KW 2 FVNR Sketch #5 107 Spare 7.5 KW 2 FVNR Sketch #5 108 Spare 7.5 KW 2 FVNR Sketch #5 109 Spare 7.5 KW 2 FVNR Sketch #5 110 Spare 7.5 KW 2 FVNR Sketch #5 111 Spare 7.5 KW 2 FVNR Sketch #5 112 Spare 7.5 KW 2 FVNR Sketch #5 113 Spare 7.5 KW 2 FVNR Sketch #5 114 Resident Engineer's Office - U24 100 Sketch #5 115 Mess Room - U25 100 Sketch #5 116 Lighting 30 Sketch #5 117 Spare 100 Sketch #5 118 Spare 100 Sketch #5 119 Spare 60 Sketch #5 120 Spare 60 Sketch #5 121 Spare 30 Sketch #5 122 Spare 30 Sketch #5 SPECIFICATION OF AERATION CONTROL PANEL U8(OB,1B): 1. For all 88 unit size2 use (13-18A) over load relay. 2. The 88unit and 22 starters starting auto sequence group by group using timers and hand by push buttons. 3. For size 4 uses (65-85A) over load relay. 4. All the motors will use overheat P.T.C. 5. Use Isolating transformer for control. 6. All starters should have local and remote control. 7. Provide 88 size 2 starters and 22 size 4. 8. The circuit breaker air 2-2500A drawable, 1-2000A air drawable, 4-100A MCCB, 2-60A MCCB, 3-30A MCCB. 9. Provide the following MCB in the lighting cubicle: 2 - 3P, 25A 2 - 3P, 16A 3 - 2P, 25A 4 - 2P, 16A 6 - 2P, 6A The motors operate 24 hours continuous duty # load list 6 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker - Transformer TR13.1 2000 Ground fault protection relay (50N) shall be provided in addition of breaker protection. Provide voltmeter, ampmeter and selector switches. 2 Final Effluent Pump Motor 85 KW 6 FVNR 3 Final Effluent Pump Motor 85 KW 6 FVNR 3NO. 4 Final Effluent Pump Motor 85 KW 6 FVNR 5 Final Effluent Pump Motor 85 KW 6 FVNR 6 Final Effluent Pump Motor 38 KW 4 FVNR 5 7 Final Effluent Pump Motor 38 KW 4 FVNR A 8 Return Sludge Pump Station 400 5 9 Lighting 60 5 10 Penstock Actuator 2.5 KW 0 FVR 11 Spare 85 kw 6 FVNR 12 Spare 100 13 Spare 100 14 Spare 30 Specification of final effluent P.S (OB1B) U11: 1. IP=41. 2. For starter size 0 FVR there is limit and torque switches working local and remote. 3. For starters size 4 FVNR and starters size 6 FVNR use star coupling starting electrolyte liquid starters, operated by push button. 4. Provide the following MCB in the lighting cubical. 2 - 3P, 25A 2 - 3P, 16A 2 - 2P, 25A 3 - 2P, 16A 5 - 2P, 6A # load list 7 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC sefty Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA factor Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker - Transformer TR14.1 630 500 Provide voltmeter, ampmeter and selector switches 2 Return Sludge Pump Motor #1 40 KW 3 FVNR 3 Return Sludge Pump Motor #2 40 KW 3 FVNR 4 Return Sludge Pump Motor #3 40 KW 3 FVNR 3NO. 5 Return Sludge Pump Motor #4 40 KW 3 FVNR 3NO. 6 Fan #1 3.5 KW 0 FVNR 7 Fan #2 3.5 KW 0 FVNR 8 Workshop 100 5 9 Warehouse 60 5 10 Lighting 30 5 Install MCB's in lighting cubical. 2 - 3 pole 25A, 2 - 3 pole 16A, 8 - 2 pole 6A, 3 -2 pole 25A, 2 - 2 pole 16A 11 Sump Pump 6 KW 1 FVNR Fu 12 Spare 100 13 Spare 60 14 Spare 30 # load list 8 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker - Transformer TR31.1 3200 3200 Ground fault protection relay (50N) shall be provided in addition of breaker protection. 2 Detritor U33 3200 3200 Provide voltmeter, ampmeter and selector switches. 3 Main Lift Pump Station U33 3200 3200 Provide voltmeter, ampmeter and selector switches. 4 Lights 60 30 Provide the following MCB in the lighting cubicle: 1-3P, 25A; 2-2P, 16A; 2-2P, 10A; 1-1P, 6A 5 Spare 200 100 6 Spare 100 60 3NO. 7 Spare 200 100 # load list 9 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC sefty Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA factor Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker - Transformer TR32.1 2500 A Transformer ground fault protection relay (50N) shaft be provided in addition of breaker protection 2 Incoming Main Circuit Breaker - Transformer TR32.2 2000 A Transformer ground fault protection relay (50N) shaft be provided in addition of breaker protection 3 Bus Tie Circuit Breaker 2000 A Bus Tie circuit breaker to be interlocked to avoid apralleling of incoming supply. Ampmeter, Voltmeter, selector switches and protective relaying to be included 4 Raw Sludge Pump Station - U37 400 A 3NO. Provide voltmeter, ampmeter and selector switch 5 Aeration Tanks - U38 400 A 3NO. Provide voltmeter, ampmeter and selector switch 6 Sludge Return Pump Station - U41 400 A 3NO. Provide voltmeter, ampmeter and selector switch 7 Motor #A1 15 KW 2 FVNR 8 Motor # A2 15 KW 2 FVNR 9 Motor # A3 15 KW 2 FVNR 10 Motor # A4 15 KW 2 FVNR 11 Motor # A5 15 KW 2 FVNR 12 Motor # A6 15 KW 2 FVNR 13 Motor # B1 15 KW 2 FVNR 14 Motor # B2 15 KW 2 FVNR 15 Motor # B3 15 KW 2 FVNR 16 Motor # B4 15 KW 2 FVNR 17 Motor # B5 15 KW 2 FVNR 18 Motor # B6 15 KW 2 FVNR 19 Motor # C1 15 KW 2 FVNR 20 Motor # C2 15 KW 2 FVNR 21 Motor # C3 15 KW 2 FVNR 22 Motor # C4 15 KW 2 FVNR 23 Motor # C5 15 KW 2 FVNR 24 Motor # C6 15 KW 2 FVNR 25 Motor # D1 15 KW 2 FVNR 26 Motor # D2 15 KW 2 FVNR 27 Motor # D3 15 KW 2 FVNR 28 Motor # D4 15 KW 2 FVNR 29 Motor # D5 15 KW 2 FVNR 30 Motor # D6 15 KW 2 FVNR 31 Motor # E1 15 KW 2 FVNR 32 Motor # E2 15 KW 2 FVNR 33 Motor # E3 15 KW 2 FVNR 34 Motor # E4 15 KW 2 FVNR 35 Motor # E5 15 KW 2 FVNR 36 Motor # E6 15 KW 2 FVNR 37 Motor # F1 15 KW 2 FVNR 38 Motor # F2 15 KW 2 FVNR 39 Motor # F3 15 KW 2 FVNR 40 Motor # F4 15 KW 2 FVNR 41 Motor # F5 15 KW 2 FVNR 42 Motor # F6 15 KW 2 FVNR 43 Motor # G1 15 KW 2 FVNR 44 Motor # G2 15 KW 2 FVNR 45 Motor # G3 15 KW 2 FVNR 46 Motor # G4 15 KW 2 FVNR 47 Motor # G5 15 KW 2 FVNR 48 Motor # G6 15 KW 2 FVNR 49 Motor # H1 15 KW 2 FVNR 50 Motor # H2 15 KW 2 FVNR 51 Motor # H3 15 KW 2 FVNR 52 Motor # H4 15 KW 2 FVNR 53 Motor # H5 15 KW 2 FVNR 54 Motor # H6 15 KW 2 FVNR 55 Motor # I1 15 KW 2 FVNR 56 Motor # I2 15 KW 2 FVNR 57 Motor # I3 15 KW 2 FVNR 58 Motor # I4 15 KW 2 FVNR 59 Motor # I5 15 KW 2 FVNR 60 Motor # I6 15 KW 2 FVNR 61 Motor # J1 15 KW 2 FVNR 62 Motor # J2 15 KW 2 FVNR 63 Motor # J3 15 KW 2 FVNR 64 Motor # J4 15 KW 2 FVNR 65 Motor # J5 15 KW 2 FVNR 66 Motor # J6 15 KW 2 FVNR 67 Spare 15 KW 2 FVNR 68 Spare 15 KW 2 FVNR 69 Spare 15 KW 2 FVNR 70 Spare 15 KW 2 FVNR 71 Spare 15 KW 2 FVNR 72 Spare 15 KW 2 FVNR 73 Spare 100 A 74 Spare 100 A 75 Spare 100 A 76 Spare 60 A 77 Spare 60 A 78 Spare 30 A SPECIFICATION OF AERATION CONTROL PENAL U39 1. The 66 motors are to start auto sequence group by group, using timers and hand by push buttons. 2. All the motors will be provided with P.T.C. 3. Provide Isolating transformer for control. 4. All starters should have local and remote control. 5. Provide the following MCB in the lighting cubicle: 2 - 3P, 25A 2 - 3P, 16A 3 - 2P, 25A 4 - 2P, 16A 6 - 2P, 6A Provide drawable starters All motors listed are of continuous duty rating # load list 10 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker - Transformer TR33.1 2500 2000 Provide ground fault protection (50N) in addition to breaker protection. Provide Voltmeter, Ampmeter and selector switches 2 Spare 60 30 3 Lighting 100 60 3NO. lighting see the MCBs 4 Spare 200 100 5 Spare 200 100 6 Spare 400 200 7 Pump Motor #1 102 KW 205 200 6 FVNR 5 star coupling electrolyte starter 8 Pump Motor #2 102 KW 205 200 6 FVNR 5 star coupling electrolyte starter 9 Pump Motor #3 102 KW 205 200 6 FVNR 5 star coupling electrolyte starter 10 Pump Motor #4 102 KW 205 200 6 FVNR 5 star coupling electrolyte starter 11 Spare 102 KW 205 200 6 FVNR 5 star coupling electrolyte starter 12 Pump Motor #6 45 KW 95 90 4 FVNR star coupling electrolyte starter 13 Pump Motor #7 45 KW 95 90 4 FVNR star coupling electrolyte starter 14 Penstock Actuator #1 3.5 KW 7 6 0 FVR Specification of final effluent P.S U42: 1. IP=42. 2. Starter size O-FVR has limit and torque switches working local and remote. 3. Starters size 4-FVNR and 6-FVNR are using star coupling starting electrolyte liquid starters working by push buttons. 4. Provide the following MCB in the lighting cubicle: 2 - 3P, 25A 2 - 3P, 16A 2 - 2P, 25A 3 - 2P, 16A 5 - 2P, 6A 5. Provide drawable starters # load list 11 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 200 100 2 Spare 60 30 3 Lighting 60 30 4 Crane 60 30 5 Spare 100 60 3NO. 6 Screen #1 4 KW 8.5 8 1 FVR 5 7 Screen #2 4 KW 8.5 8 1 FVR 5 8 Screen #3 4 KW 8.5 8 1 FVR 5 9 Screen #4 4 KW 8.5 8 1 FVR 5 10 Conveyor #1 1.5 KW 6 5 0 FVNR 11 Conveyor #2 1.5 KW 6 5 0 FVNR 12 Fan #1 2.5 KW 6 5 0 FVNR 13 Fan #2 2.5 KW 6 5 0 FVNR 14 Penstock Actuator #1 2 KW 7 6 0 FVR 15 Penstock Actuator #2 2 KW 7 6 0 FVR 16 Spare 2 KW 7 6 0 FVR screen house U2 1. There is high level of H2S and CH4 (EX) panel . 2. Use aluminum bus bars. 3. Provide the following MCB in the lighting cubicle: · 1 - 3P, 25A · 1 - 3P, 16A · 2 - 2P, 25A · 3 - 2P, 16A · 8 - 2P, 6A 4. Use side waterproof socket (3P, 30A). 5. The (1 FVR size) starter works in three modes [hand (push buttons)/off/Auto (pulse timers)] with high water level stop. # load list 12 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker #1 3200 3200 Transformer ground fault protection relay (50N) shall be provided in addition of breaker protection. Provide Voltmeter, Ampmeter and selector switches. 2 Incoming Main Circuit Breaker #2 s 3200 3200 Transformer ground fault protection relay (50N) shall be provided in addition of breaker protection. Provide Voltmeter, Ampmeter and selector switches. 3 Bus Tie Breaker 3200 3200 Bus Tie circuit breaker to be interlocked to avoid apralleling of incoming supply. Ampmeter, voltmeter, selector switches and protective relaying to be included 1 Lighting 60 30 2 Spare 100 60 3NO. 3 Spare 200 100 4 Spare 400 200 5 Main Lift Pump Motor #1 250 KW 520 500 7 FVNR 5 6 Main Lift Pump Motor #2 250 KW 520 500 7 FVNR 5 7 Main Lift Pump Motor #3 160 KW 325 315 6 FVNR 8 Main Lift Pump Motor #4 160 KW 325 315 6 FVNR 9 Main Lift Pump Motor #5 90 KW 185 180 FVNR 1 Main Lift Pump Motor #6 160 KW 325 315 6 FVNR 2 Main Lift Pump Motor #7 160 KW 325 315 6 FVNR 3 Spare 250 KW 520 500 7 FVNR 5 4 Spare 250 KW 520 500 7 FVNR 5 5 Main Lift Pump Motor #8 90 KW 185 180 FVNR 6 Sump Pump #1 15 KW 32 30 2 FVNR 7 Sump Pump #2 15 KW 32 30 2 FVNR 8 Fan #1 5 KW 10 8 1 FVNR 9 Fan #2 5 KW 10 8 1 FVNR 10 Actuator #1 0.5 KW FVR 11 Actuator #2 0.5 KW FVR 12 Actuator #3 0.5 KW FVR 13 Actuator #4 0.5 KW FVR 14 Actuator #5 0.5 KW FVR 15 Actuator #6 0.5 KW FVR 16 Actuator #7 0.5 KW FVR 17 Actuator #8 0.5 KW FVR 18 Actuator #9 0.5 KW FVR 19 Actuator #10 0.5 KW FVR 20 Actuator #11 0.5 KW FVR 21 Actuator #12 0.5 KW FVR 22 Actuator #13 0.5 KW FVR 23 Actuator #14 0.5 KW FVR 24 Actuator #15 0.5 KW FVR 25 Actuator #16 0.5 KW FVR 26 Actuator #17 0.5 KW FVR 27 Actuator #18 0.5 KW FVR 28 Actuator #19 0.5 KW FVR 29 Actuator #20 0.5 KW FVR 30 Main Actuator Circuit Breaker #1 100 31 Main Actuator Circuit Breaker #2 100 THE SPECIFICATION OF MAIN LIFT P.S. 2nd EXPANSION: 1. IP=42 2. Starters size O-FVR will have limit, torque and remote switches with local control. 3. Starters sizes 6 & 7 will use electrolyte liquid starting (star coupling) with auto by water level control system, hand by push buttons. 4. The power factor correction unit will be provided and located in a separate panel and have its own control to keep the P.F. 0.95lag. 5. There is MMIC showing the flow, indicators and remote control operation and monitoring. 6. In this MCClifting station we have three (3) panels. The first is for MMIC and air C.Bs. The second is for 10 starters size O-FVR, 5 Pump starters, one sump pump starter, one fan starter, 3MCCB, level control system for 4 7. Provide the following MCB in the lighting cubicle: · 3 - 3P, 25A · 3 - 3P, 16A · 5 - 2P, 25A · 5 - 2P, 10A · 2P 6A 8NO. · 2P 2A 4NO. 8. Provide drawable starters # load list 13 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker 200 100 2 Lighting 60 30 3 Detritor Group #2 100 60 3NO. 4 Spare 100 60 3NO. 5 Spare 60 30 6 Classifier #1 2.2 KW 5 4.5 0 FVNR 5 7 Classifier #2 2.2 KW 5 4.5 0 FVNR 5 8 Scraper #1 1.5 KW 3.5 3 0 FVNR 9 Scraper #2 1.5 KW 3.5 3 0 FVNR 10 Mixer #1 0.75 KW 2 1.5 0 FVNR 11 Mixer #2 0.75 KW 2 1.5 0 FVNR 12 Penstock Actuator #1 0.55 KW 1.5 1.25 0 FVR 13 Penstock Actuator #2 0.55 KW 1.5 1.25 0 FVR 14 Penstock Actuator #3 0.55 KW 1.5 1.25 0 FVR 15 Penstock Actuator #4 0.55 KW 1.5 1.25 0 FVR 16 Penstock Actuator #5 0.55 KW 1.5 1.25 0 FVR 17 Penstock Actuator #6 0.55 KW 1.5 1.25 0 FVR 18 Spare 0.55 KW 1.5 1.25 0 FVNR SPECIFICATION OF DETRITOR GROUP1 U33: 1. IP=56 out door. 2. Starters size O-FVR are local and remote control, the starters load will have limit and torque switches. 3. Starters size O-FVNR will have local and remote control with three mode selector. Auto by pulse timers and hand by selector switches. 4. Provide the following MCB in the lighting cubicles. · 1 - 3P, 25A · 2 - 2P, 25A · 2 - 2P, 16A · 5 - 2P, 6A 5. The total number of starters will be 6-0 FVR and 7-O FVNR. # load list 14 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 2 200 100 2 Lighting 2 60 30 3 Spare 2.5 60 30 4 Spare 100 60 5 Classifier #1 2.2 KW 5 4.5 3 0 FVNR 5 6 Classifier #2 2.2 KW 5 4.5 3 0 FVNR 5 7 Scraper #1 1.5 KW 3.5 3 3 0 FVNR 8 Scraper #2 1.5 KW 3.5 3 3 0 FVNR 9 Mixer #1 0.75 KW 2 1.5 2.5 0 FVNR 10 Mixer #2 0.75 KW 2 1.5 2.5 0 FVNR 11 Penstock Actuator #1 0.55 KW 1.5 1.25 2.5 0 FVR Full Voltage Reversing 12 Penstock Actuator #2 0.55 KW 1.5 1.25 2.5 0 FVR Full Voltage Reversing 13 Penstock Actuator #3 0.55 KW 1.5 1.25 2.5 0 FVR Full Voltage Reversing 14 Penstock Actuator #4 0.55 KW 1.5 1.25 2.5 0 FVR Full Voltage Reversing 15 Penstock Actuator #5 0.55 KW 1.5 1.25 2.5 0 FVR Full Voltage Reversing 16 Penstock Actuator #6 0.55 kw 1.5 1.25 2.5 0 FVR Full Voltage Reversing 17 Spare 0.55 KW 1.5 1.25 2.5 0 FVNR Full Voltage Non Reversing SPECIFICATION OF DETRITOR GROUP1 U33: 1. IP=56 out door. 2. Starters size O FVR are local and remote control, the starters load will have limit and torque switches. 3. Starters size O FVNR will have local and remote control with three mode selector auto by pulse timers hand by selector switches. 4. Provide the following MCB in the lighting cubicle. · 1 - 3P, 25A · 2 - 2P, 25A · 2 - 2P, 16A · 5 - 2P, 6A 5. Provide drawable starters # load list 15 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker 400 2 Lighting 60 30 3 Spare 60 30 4 Spare 60 30 5 Settling Tank Lights #1 60 30 6 Spare 60 30 7 Settling Tank Group #1 Main Breaker 100 60 3NO. 8 Spare 100 60 3NO. 9 Settling Tank Group #2 Main Breaker 200 100 10 Spare 200 100 11 Settling Tank Lights #2 60 30 12 Settling Tank Scraper #1 250 W 0 FVNR 5 12 Settling Tank Scraper #2 250 W 0 FVNR 5 12 Settling Tank Scraper #3 250 W 0 FVNR 5 12 Settling Tank Scraper #4 250 W 0 FVNR 5 12 Settling Tank Scraper #5 250 W 0 FVNR 5 12 Settling Tank Scraper #6 250 W 0 FVNR 5 12 Settling Tank Scraper #7 250 W 0 FVNR 5 12 Settling Tank Scraper #8 250 W 0 FVNR 5 12 Spare 250 W 0 FVNR 5 12 Spare 250 W 0 FVNR 5 13 Raw Sludge Pump #1 11 KW 23 22 2 Star Delta star delta 14 Raw Sludge Pump #2 11 KW 23 22 2 Star Delta star delta 15 Raw Sludge Pump #3 11 KW 23 22 2 Star Delta star delta 16 Raw Sludge Pump #4 11 KW 23 22 2 Star Delta star delta 17 Raw Sludge Pump #5 11 KW 23 22 2 Star Delta star delta 18 Spare 11 KW 23 22 2 Star Delta star delta 19 Pre-Aerator #1 15 KW 32 30 2 FVNR 20 Pre-Aerator #1 15 KW 32 30 2 FVNR 21 Pre-Aerator #1 15 KW 32 30 2 FVNR Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 22 Pre-Aerator #4 15 KW 32 30 2 FVNR 22 Spare 15 KW 32 30 2 FVNR 23 Fan #1 3 KW 10 8 1 FVNR 24 Fan #2 3 KW 10 8 1 FVNR SPECIFICATION OF RAW SLUDGE P.S. U37PRE AERATOR U34 SETTING TANK U35: 1. IP=42 2. For starters size O auto by pulse timer hand by selector switches with local and remote start stop, the load will have torque switches. 3. For starters size 2 use star delta starter auto by water level control system hand by push buttons. 4. For starters size 2 FVNR use auto by pulse timers hand by selector switches with local and remote start stop. 5. Provide the following MCB in the lighting cubicle. 2 - 3P, 25A 2 - 3P, 16A 3 - 2P, 25A 3 - 2P, 16A 8 - 2P, 6A # load list 16 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Lights Circuit Breaker 60 30 2 Lights Circuit Breaker 60 30 3 Lights Circuit Breaker 60 30 4 Lights Circuit Breaker 60 30 5 Settling Tank Main Circuit Breaker #1 100 60 6 Settling Tank Main Circuit Breaker #2 100 60 3NO. 7 Spare 60 30 3NO. 8 Spare 100 60 3NO. 9 Spare 200 100 10 Main Circuit Breaker 600 400 11 Settling Tank #1 250 W 0 FVNR 5 12 Settling Tank #2 250 W 0 FVNR 5 13 Settling Tank #3 250 W 0 FVNR 5 14 Settling Tank #4 250 W 0 FVNR 5 15 Settling Tank #5 250 W 0 FVNR 5 16 Settling Tank #6 250 W 0 FVNR 5 17 Settling Tank #7 250 W 0 FVNR 5 18 Settling Tank #8 250 W 0 FVNR 5 19 Spare 250 W 0 FVNR 5 20 Spare 250 W 0 FVNR 5 21 Screw Pump #1 15 KW 2 Star Delta 2 speed 22 Screw Pump #2 15 KW 2 Star Delta 2 speed 23 Screw Pump #3 15 KW 2 Star Delta 2 speed 24 Screw Pump #4 15 KW 2 Star Delta 2 speed 25 Spare 15 KW 2 Star Delta 2 speed 26 Sump Pump #1 20 KW 3 FVNR 27 Sump Pump #2 20 KW 3 FVNR SPECIFICATION FOR RETURN SLUDGE P.S. U40 U41: 1. IP=42, for size O starters use, hand by selector switches, with remote and local start stop. 2. For size 2 star delta use hand by selector switches, auto by water level system control. 3. The load which is connected to the size 0 starters have torque switches. 4. Provide the following MCBs in the lighting cubicle. · 2 -3P, 23A · 2 - 2P, 25A · 5 - 2P, 6A 5. The starter size O 10NO.size254NO.size 3 2NO. 6. The motors size 15KW with two speeds and the starting will be from low to up. # load list 17 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 600 400 2 Lighting 60 30 3NO. 3 Spare 200 100 4 Spare 100 60 5 Fan #1 2.5 KW 0 FVNR 5 6 Fan #2 2.5 KW 0 FVNR 5 7 Spare 10 1 FVNR 8 Main Sludge Pump #1 30 KW 3 FVNR electrolyte star coupling 9 Main Sludge Pump #2 30 KW 3 FVNR electrolyte star coupling 10 Main Sludge Pump #3 30 KW 3 FVNR electrolyte star coupling 11 Main Sludge Pump #4 30 KW 3 FVNR electrolyte star coupling 12 Sump Pump 4.5 KW 0 FVNR 13 Spare 30 KW 3 FVNR electrolyte star coupling SPECIFICATION OF MAIN SLUDGE P.S.U38: 1. IP=42, Provide drawable starters 2. The size 3 starters use electrolyte liquid starting (star coupling) working by auto use water level control system hand by push buttons. 3. Provide the following MCBs in the lighting cubicle. 1 - 3P, 25A 2 - 3P, 16A 2 - 2P, 25A 2 - 2p, 16A 5 - 2P, 6A # load list 18 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 200 100 2 Lighting 60 30 3 Crane 60 30 4 Spare 60 30 5 Spare 100 60 3NO. 6 Screen #1 4 KW 0 FVR 5 7 Screen #2 4 KW 0 FVR 5 8 Screen #3 4 KW 0 FVR 5 9 Screen #4 4 KW 0 FVR 5 10 Penstock #1 2 KW 0 FVR 11 Penstock #2 2 KW 0 FVR 12 Belt Conveyor #1 1.5 KW 0 FVNR 13 Belt Conveyor #2 1.5 KW 0 FVNR 14 Fan #1 2.5 KW 0 FVNR 15 Fan #2 2.5 KW 0 FVNR 16 Spare 0 FVR screen house U31 1. There is high level of H2S and CH4 (EX) panel . 2. Use aluminum bus bars. 3. for lighting cubical #1 Use M.C.B. as: · 1 - 3P, 25A · 1 - 3P, 16A · 2 - 2P, 25A · 3 - 2P, 16A · 8 - 2P, 6A 4. Provide side waterproof socket (3P, 30A). 5. The size 1 FVR starter works in three modes [hand (push buttons)/off/Auto (pulse timers)] with high water level stop. 6. Provide the following MCBs in the lighting cubicle. 1 - 3P, 25A 1 - 2P, 25A 2 - 2P, 16A 5 - 2P, 6A # load list 19 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker #1 200 200 2 Main Circuit Breaker #2 200 200 3 Actuators Circuit Breaker #1 100 60 4 Acturators Circuit Breaker #2 100 60 5 Screen Motor 200 100 6 Lighting/Receptacles 60 30 3NO. 7 Spare 100 60 3NO. 8 Spare 200 100 3NO. 9 Sump Pump #1 12.5 KW FVNR 5 10 Sump Pump #2 12.5 KW FVNR 5 11 Fan #1 5 KW FVNR 5 12 Fan #2 5 KW FVNR 13 Spare KW 2 FVNR 14 Aeration Actuator #1 0.5 KW 0 FVR 15 Aeration Actuator #2 0.5 KW 0 FVR 16 Aeration Actuator #3 0.5 KW 0 FVR 17 Aeration Actuator #4 0.5 KW 0 FVR 18 Aeration Actuator #5 0.5 KW 0 FVR 19 Aeration Actuator #6 0.5 KW 0 FVR 20 Aeration Actuator #7 0.5 KW 0 FVR 21 Aeration Actuator #8 0.5 KW 0 FVR 22 Aeration Actuator #9 0.5 KW 0 FVR 23 Aeration Actuator #10 0.5 KW 0 FVR 24 Aeration Actuator #11 0.5 KW 0 FVR 25 Aeration Actuator #12 0.5 KW 0 FVR 26 Aeration Actuator #13 0.5 KW 0 FVR 27 Aeration Actuator #14 0.5 KW 0 FVR 28 Aeration Acturator #15 0.5 KW 0 FVR 29 Aeration Acturator #16 0.5 KW 0 FVR 30 Spare 0.5 KW 0 FVR 31 Spare 0.5 KW 0 FVR 32 Spare 0.5 KW 0 FVR 33 Spare 0.5 KW 0 FVR Main lift P.S U1: 1. IP=42 2. There are 20 size 0 FVR starters with remote start/stop and limit switches and torque switches. 3. For sump pumps with the size2 starter provide a Ammeter. 4. Provide the following MCBs for the lighting cubicle. 2 - 3p, 25A MCB 1 - 3P, 16A MCB 3 - 2P, 25A MCB 2 - 2P, 16A MCB 6 - 2P, 6A MCB 5. For spare MCCB use cubical for each. 6. The MMIC shall have a flow (m^3), recorder, meters KV, A, KW. see the attach no.56230x207 # load list 21 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 200 100 2 Lighting 60 30 3 Detritor 1B 100 60 3NO. 4 Spare 100 60 3NO. 5 Scraper #1 1.5 KW 0 FLNR 6 Scraper #2 1.5 KW 0 FLNR 7 Classifier #1 2.2 KW 0 FLNR 8 Classifier #2 2.2 KW 0 FLNR 9 Mixer #1 0.75 KW 0 FLNR 10 Mixer #2 0.75 KW 0 FLNR 11 Spare 3 KW 0 FLNR 12 Spare 3 KW 0 FLR 13 Penstock Acutator #1 3 KW 0 FLR 14 Penstock Acutator #2 3 KW 0 FLR 15 Penstock Acutator #3 3 KW 0 FLR 16 Penstock Acutator #4 3 KW 0 FLR 17 Penstock Acutator #5 3 KW 0 FLR Detritors (OB) specification: 1. IP=56 (out door) use aluminum bus bar. 2. All starters use local and remote operate. 3. In all starters load there are torque switches the actuators starters use limit switches. 4. Size O starters use hand/off/auto, hand by selector switch, and auto by pulse timer. 5. Provide the following MCB in the lighting cubical: · 1 - 3P, 25A · 1 - 3P, 16A · 3 - 2P, 16A · 5 - 2P, 6A 6. Provide drawable starters # load list 22 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 100 60 2 Lighting 60 30 3 Spare 60 30 3NO. 4 Classifier 2.5 KW 0 FVNR 5 Scrubber 1.5 KW 0 FVNR 6 Mixer 0.75 KW 0 FVNR 7 Spare 4 KW 0 FVR 8 Penstock Actuator #1 1.5 KW 0 FVR 9 Penstock Actuator #2 1.5 KW 0 FVR Specification of 1B detritor: 1. IP=56 (out door) use aluminum bas bar. 2. All starters using local and remote start/stop switches. 3. All starters using torques and limits switches. 4. The size O starters use hand, off, auto hand by selector switches, auto by pulse timers. 5. Provide drawable starters 6. lighting cubical use the following MBC: 1 - 3P, 25A 1 - 3P, 16 1 - 2P, 25A 6 - 2p, 6A # load list 23 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size Sheet Change Available REMARKS 1 Main Cricuit Breaker 100 60 2 Spare 60 30 3 Lighting 60 30 3NO. 4 Skimmer 1.5 KW 0 FVNR 5 Penstock Actuator #1 0.55 KW 0 FVR 6 Penstock Actuator #2 0.55 KW 0 FVR Specification for grease removing U4: 1. IP=54 (out door). 2. Use aluminum bus bars. 3. Size 0 starters use remote hand/off/auto switch and are auto by pulse timer. 4. In lights cubical use MCB: 1 - 3P, 16A 1 - 2P, 16A 4 - 2P, 6A # load list 24 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 400 400 2 Spare 100 60 3 Settling tank #1 lighting 60 30 4 Settling tank #2 lighting 60 30 5 Settling Tank #1 Main Circuit Breaker 100 60 6 Lighting 60 30 7 Spare 60 30 3NO. 8 Settling Tank #2 Main Circuit Breaker 100 60 3NO. 9 Spare 200 100 3NO. 10 Fan #1 2.5 KW 0 FVNR 11 Fan #2 2.5 KW 0 FVNR 12 Fan #3 2.5 KW 0 FVNR 13 Spare 7.5 KW 1 FVNR 14 Pump #1 7.5 KW 1 FVNR 15 Pump #2 7.5 KW 1 FVNR 16 Pump #3 7.5 KW 1 FVNR 17 Sump Pump 1 KW 0 FVNR 18 Settling Tank #1 0.55 KW 0 FVNR 19 Settling Tank #2 0.55 KW 0 FVNR 20 Settling Tank #3 0.55 KW 0 FVNR 21 Settling Tank #4 0.55 KW 0 FVNR 22 Settling Tank #5 0.55 KW 0 FVNR 23 Settling Tank #6 0.55 KW 0 FVNR 24 Settling Tank #7 0.55 KW 0 FVNR 25 Settling Tank #8 0.55 KW 0 FVNR 26 Spare 0.55 KW 0 FVNR 27 Spare 0.55 KW 0 FVNR RAW SLUDGE P.S. OB U6 1. IP=42. 2. Size O starters are controlled in auto mode by pulse timer and hand mode by selector switches. The load uses torque switches. 3. Size 1 starters are controlled in auto mode by water level control system using electrolyte liquid starter (star coupling) and in hand mode by push buttons. 4. In lights cubical use the following MCB: 1 - 3P, 25A 2 - 2P, 16A 6 - 2P, 6A # load list 25 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker 400 400 2 Spare 200 100 3 Lighting 60 30 4 Spare 100 60 3NO. 5 Fan #1 2.5 KW 0 FVNR 6 Fan #2 2.5 KW 0 FVNR 7 Main Sludge Pump Motor #1 11 KW 23 22 2 FVNR star coupling 8 Main Sludge Pump Motor #2 11 KW 23 22 2 FVNR star coupling 9 Main Sludge Pump Motor #3 11 KW 23 22 2 FVNR star coupling 10 Main Sludge Pump Motor #4 11 KW 23 22 2 FVNR star coupling 11 Sump Pump 5 KW 12 10 1 FVNR 12 Spare 11 KW 2 FVNR SPECIFICATION OF MAIN SLUDGE P.S.(OB,1B): 1. IP=42. 2. The starters size 2 using electrolyte starters. 3. Starters (size 2) (hand by push buttons),(auto by water level control system). 4. For lighting cubical use: 2 - 3P, 25A 2 - 3P, 16A 1 - 2P, 25A 2 - 2P, 16A 6 - 2P, 6A # load list 26 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Incoming Main Circuit Breaker 400 200 2 Lighting 60 30 2 Spare 60 30 3 Spare 100 60 3NO. 4 Settling Tank #1 1.1 KW 0 FVNR 5 Settling Tank #2 1.1 KW 0 FVNR 6 Fan #1 2.5 KW 0 FVNR 7 Fan #2 2.5 KW 0 FVNR 8 Sump Pump 4 KW 0 FVNR 9 Raw Sludge Pump Motor #1 11 KW 23 20 2 Star Delta 10 Raw Sludge Pump Motor #2 11 KW 23 20 2 Star Delta 11 Spare 11 KW 23 20 2 Star Delta 12 Spare 4 KW 0 FVNR RAW SLUDGE P.S.(1B) (U6+U5): 1) IP=42. 2) Size O starters working auto by pulse timer hand by selector switches, the load use torque switch. 3) Size 2 starters working auto by water level control system hand by push buttons. 4) in lights cubical use the following MCB: 1 - 3P, 25A 2 - 2P, 16A 6 - 2P, 6A 5) Add one (1) outdoor j- box with remote start/stop switches for settling tank starters. # load list 27 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 600 400 2 Spare 200 100 3 Lighting Circuit Breaker #1 60 30 4 Lighting Circuit Breaker #2 60 30 5 Lighting Circuit Breaker #3 60 30 6 Spare 60 30 7 Spare 100 60 8 Final Settling Tank Main Circuit Breaker 200 100 3NO. 9 Return Sludge Pump Motor #1 15 KW 3 Star Delta 10 Return Sludge Pump Motor #2 15 KW 3 Star Delta 11 Return Sludge Pump Motor #3 15 KW 3 Star Delta 12 Return Sludge Pump Motor #4 15 KW 3 Star Delta 13 Sump Pump #1 20 KW 3 FVNR 14 Sump Pump #2 20 KW 3 FVNR 15 Final Settling Tank #1 1.1 KW 0 FVNR 16 Final Settling Tank #2 1.1 KW 0 FVNR 17 Final Settling Tank #3 1.1 KW 0 FVNR 18 Final Settling Tank #4 1.1 KW 0 FVNR 19 Final Settling Tank #5 0.55 KW 0 FVNR 20 Final Settling Tank #6 0.55 KW 0 FVNR 21 Final Settling Tank #7 0.55 KW 0 FVNR 22 Final Settling Tank #8 0.55 KW 0 FVNR 23 Spare KW 0 FVNR 24 Spare KW 0 FVNR SPECIFICATION FOR RETURN SLUDGE P.S. U10: 1. IP=42. Size O starters are to operated both romote and local stop/start. 2. Star Delta starters operate hand by selector switch and auto by water level system control. 3. Lights cubical use the following MCB: · 2- 3P, 23A · 2 -2P, 25A · 2 - 2P, 6A 4. The 22KW motors shall have two speeds and the starting should be from low to high. # load list 28 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC safety Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA factor Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 200 100 3NO. 2 Spare 60 30 3 Air Blower #1 15 KW 32 30 2.5 2 Star Delta 5 Star delta 4 Air Blower #2 15 KW 32 30 2.5 2 Star Delta 5 Star delta Air Blower in SS11: 1. IP=42 2. Control for the Air Blowers operate hand/off/auto hand by selector switch. Auto by pulse timer or hand individually or hand both as required. # load list 32 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 200 100 3NO. 2 Lighting 60 30 3NO. 3 Receptacles/Sockets 100 60 3NO. 4 Spare 100 60 5 Spare 200 100 6 Lath KW 0 FVNR 5 7 Saw KW 0 FVNR 5 SPECIFICATION OF WORKSHOP U23: 1. IP=54. 2. Lighting cubical MCB: 4 - 3P, 25A 3 - 3P, 16A 3 - 2P, 25A 3 - 2p, 16A 8 - 2P, 6A # load list 33 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 1 Main Circuit Breaker 100 60 3NO. 2 Lighting Circuit Breaker #1 60 30 3NO. 3 Lighting Circuit Breaker #2 60 30 3NO. 4 Spare 100 60 3NO. 5 Spare 60 30 3NO. Specification of the warehouse panel U23:(Store) 1. IP=56. 2. The lighting cubicles have MCB: 2 - 3p, 25A 1 - 3P, 16A 2 - 2P, 25A 10 - 2P, 6A # load list 34 Nameplate Coect. Ope- Starter Breaker Cable Schematic Vendor Field Spare MCC cubicle Engraving Connected rating LRC SF Over Drawing Data TO Components Cubicle volume (Description) Load FLA FLA Size Type MCP Gnd Load Frame Trip Size No. Sheet Change Available REMARKS 2 Main circuit Breaker 100 60 3 Lighting 60 30 3NO. 3 Spare 60 30 3NO. 7 Sump pump 3.5 KW 7 6 0 FVNR 7 Motor #1 7.5 KW 15 14 1 FVNR 7 Motor #2 7.5 KW 15 14 1 FVNR Specification of drinking water P.S. 1. IP=56. 2. Starters are to be remotely operated. 3. Size 1 starters operate in auto mode by pulse timer or by hand mode individually. 4. Lighting cubicle · 1 - 3P, 25A MCB · 2 - 3P, 16A MCB · 6 - 2P, 6A MCB